Skip to main content

Dental Instruments & Supplies

SKU: MMI-53-027-00
Category:
Availability: In Stock

Cryer Root Elevator

Cryer Root Elevator Fig. 27 is a precision dental instrument designed for controlled elevation of teeth and tooth roots during extraction procedures. Its 11.2 mm broad angled working end provides increased contact coverage for controlled root engagement and manipulation. The precision-shaped triangular tip supports accurate positioning, while the robust shaft facilitates stable handling and controlled force application. Manufactured from surgical grade stainless steel with a polished finish, this root elevator provides durability, corrosion resistance, easy maintenance and reliable performance for repeated professional dental use.

Quantity:
0
My Custom Kit 0 items configured

Review Kit (0 items)

  • Your kit is currently empty.

Surgical Grade Material

Crafted from high-quality surgical stainless steel.

Precision Finish

Smooth finish for reliable clinical performance.

Ergonomic Design

Comfortable grip for improved control and handling.

Long Service Life

Built for durability and repeated professional use.

shield-check

Easy Sterilization

Fully autoclavable for safe and efficient sterilization.

Technical Specifications
Specification Details
Product Name Cryer Root Elevator Fig. 27
Model Number MMI-53-027-00
Instrument Type Dental Root Elevator
Pattern Cryer Fig. 27
Design Angled Working End
Application Tooth and Root Elevation
Working End Broad, Angled and Tapered
Tip Design Precision-Shaped Triangular Tip
Working Profile Broad
Working End Width 11.2 mm
Shaft Angled
Material Premium Surgical Grade Stainless Steel
Finish High-Polish Finish
Construction Precision-Forged and Hand-Finished
Sterilization Fully Autoclavable
Reusable Yes
Application Area Professional dental extraction and root elevation procedures

Description

Cryer Root Elevator Fig. 27 is a precision dental instrument designed for controlled elevation of teeth and tooth roots during dental extraction procedures. The MMI-53-027-00 features a broad, angled working end that provides a defined contact surface for controlled engagement with tooth and root structures.

The Fig. 27 configuration has an 11.2 mm working-end width, providing a broad working profile for applications requiring increased contact coverage. The corresponding KLS Martin instrument, reference 42-027-00-07, is specifically listed as a Cryer root elevator with an 11.2 mm working-end width.

Its angled working end and precision-shaped tip allow controlled positioning against the tooth or root during elevation. The broad profile provides a substantial contact area, while the tapered transition supports accurate placement and controlled manipulation.

The robust shaft provides stability during use and allows controlled application of force. Manufactured from surgical grade stainless steel, the instrument is designed for durability, corrosion resistance and repeated professional use. Its polished finish supports efficient cleaning and maintenance, while its reusable construction is suitable for appropriate sterilization between procedures.

To maintain the performance, appearance, and service life of your stainless steel dental and surgical instruments, follow these care guidelines:

  • Clean instruments immediately after use to prevent blood, tissue, or debris from drying on the surface.
  • Wash using a neutral pH enzymatic detergent and a soft nylon brush. Avoid abrasive pads, steel wool, or harsh chemicals.
  • Rinse thoroughly with distilled or demineralized water to minimize mineral deposits and corrosion.
  • Dry completely before sterilization or storage, paying special attention to hinges, joints, and serrations where moisture can accumulate.
  • Lubricate hinged and moving instruments regularly with a medical-grade, steam-permeable instrument lubricant to ensure smooth operation.
  • Sterilize using validated autoclave procedures or other approved sterilization methods according to healthcare facility protocols and the instrument’s intended use.
  • Store instruments in a clean, dry environment with tips and cutting edges protected from impact or contact with other instruments.
  • Inspect instruments before each use for wear, corrosion, misalignment, or damage. Remove any defective instrument from service until repaired or replaced.
  • Do not expose stainless steel instruments to bleach, strong acids, high-chloride solutions, or prolonged soaking, as these may cause staining, pitting, or corrosion.
  • Use each instrument only for its intended purpose to preserve precision, functionality, and patient safety.
  • Cryer Fig. 27 root elevator configuration.
  • Designed for controlled tooth and root elevation.
  • 11.2 mm working-end width provides a broad contact profile.
  • Broad, angled working end facilitates controlled positioning.
  • Precision-shaped triangular working tip supports accurate engagement.
  • Tapered working profile provides controlled contact with tooth and root structures.
  • Robust angled shaft supports stable instrument handling.
  • Surgical grade stainless steel construction provides durability and corrosion resistance.
  • High-polish finish supports cleaning and maintenance.
  • Reusable and autoclavable for professional dental applications.
  • Individually poly packed
  • Non-sterile
  • Reusable medical instrument