Skip to main content

Dental Instruments & Supplies

SKU: MMI-64-154
Availability: In Stock

Gracey Periodontal Curette Fig. 13/14

The Gracey Fig. 13/14 Periodontal Curette is a double-ended periodontal instrument featuring curved working ends, angled terminal shanks and a cylindrical knurled handle. Its area-specific Gracey design is intended primarily for periodontal instrumentation of the distal surfaces of premolars and molars. The two working ends provide different orientations within a single instrument, supporting access during posterior periodontal procedures. Its established design and stainless steel construction make it suitable for professional dental hygiene and periodontal instrument sets.

Quantity:
0
My Custom Kit 0 items configured

Review Kit (0 items)

  • Your kit is currently empty.

Surgical Grade Material

Crafted from high-quality surgical stainless steel.

Precision Finish

Smooth finish for reliable clinical performance.

Ergonomic Design

Comfortable grip for improved control and handling.

Long Service Life

Built for durability and repeated professional use.

shield-check

Easy Sterilization

Fully autoclavable for safe and efficient sterilization.

Technical Specifications
Specification Details
Product Name Gracey Periodontal Curette, Fig. 13/14
Model Number MMI-64-154
Instrument Type Periodontal curette
Pattern / Figure Gracey Fig. 13/14
Design Double-ended Gracey curette
Application Periodontal debridement and root-surface instrumentation
Working Ends Double-ended
Tip Design Curved Gracey curette working ends
Working Profile Angled, site-specific curette profile
Shaft Angled terminal shanks
Handle Cylindrical knurled handle
Material Surgical Grade Stainless Steel
Finish Metallic finish
Construction Double-ended hand instrument
Sterilization Autoclavable
Reusable Yes
Application Area Periodontology / Dental Hygiene

Description

The Gracey Periodontal Curette Fig. 13/14 is a double-ended periodontal instrument designed for professional periodontal debridement and root-surface instrumentation. The supplied image shows the characteristic Gracey configuration with two curved working ends, angled terminal shanks and a cylindrical knurled handle. The catalogue/model number printed on the image is MMI-64-154, corresponding to Gracey Fig. 13/14 in established dental instrument catalogues.

The Fig. 13/14 pattern is an area-specific Gracey curette intended primarily for the distal surfaces of posterior teeth, including premolars and molars. Manufacturer references specify the working orientation for disto-buccal and disto-lingual posterior surfaces.

The double-ended construction provides two working ends in different orientations within one instrument. Its angled shanks and curved working profiles are characteristic of the Gracey curette design. Manufactured from Surgical Grade Stainless Steel, the instrument is suitable for repeated professional use and routine autoclave sterilization.

To maintain the performance, appearance, and service life of your stainless steel dental and surgical instruments, follow these care guidelines:

  • Clean instruments immediately after use to prevent blood, tissue, or debris from drying on the surface.
  • Wash using a neutral pH enzymatic detergent and a soft nylon brush. Avoid abrasive pads, steel wool, or harsh chemicals.
  • Rinse thoroughly with distilled or demineralized water to minimize mineral deposits and corrosion.
  • Dry completely before sterilization or storage, paying special attention to hinges, joints, and serrations where moisture can accumulate.
  • Lubricate hinged and moving instruments regularly with a medical-grade, steam-permeable instrument lubricant to ensure smooth operation.
  • Sterilize using validated autoclave procedures or other approved sterilization methods according to healthcare facility protocols and the instrument’s intended use.
  • Store instruments in a clean, dry environment with tips and cutting edges protected from impact or contact with other instruments.
  • Inspect instruments before each use for wear, corrosion, misalignment, or damage. Remove any defective instrument from service until repaired or replaced.
  • Do not expose stainless steel instruments to bleach, strong acids, high-chloride solutions, or prolonged soaking, as these may cause staining, pitting, or corrosion.
  • Use each instrument only for its intended purpose to preserve precision, functionality, and patient safety.
  • Gracey Fig. 13/14 periodontal curette pattern.
  • Double-ended instrument configuration.
  • Two curved curette working ends.
  • Angled terminal shanks.
  • Site-specific Gracey working-end geometry.
  • Designed for distal surfaces of posterior teeth.
  • Suitable for premolar and molar instrumentation.
  • Cylindrical handle design.
  • Knurled gripping surface for controlled handling.
  • Individually poly packed
  • Non-sterile
  • Reusable medical instrument