Gracey Periodontal Curette, Fig. 12/13

The Gracey Fig. 12/13 Periodontal Curette is a double-ended periodontal instrument featuring curved working ends, angled terminal shanks and a cylindrical knurled handle. Its area-specific Gracey configuration provides two working orientations for periodontal debridement and root-surface instrumentation. The offset working profile supports access during periodontal procedures, while the textured handle provides a conventional gripping surface for manual handling. Manufactured from stainless steel, it is suitable for professional dental hygiene and periodontal instrument sets.

Quantity:
0
My Custom Kit 0 items configured

Review Kit (0 items)

  • Your kit is currently empty.

Surgical Grade Material

Crafted from high-quality surgical stainless steel.

Precision Finish

Smooth finish for reliable clinical performance.

Ergonomic Design

Comfortable grip for improved control and handling.

Long Service Life

Built for durability and repeated professional use.

shield-check

Easy Sterilization

Fully autoclavable for safe and efficient sterilization.

Technical Specifications
Specification Details
Product Name Gracey Periodontal Curette, Fig. 12/13
Model Number MMI-64-163
Instrument Type Periodontal curette
Pattern / Figure Gracey Fig. 12/13
Design Double-ended Gracey periodontal curette
Application Periodontal debridement and root-surface instrumentation
Working Ends Double-ended
Tip Design Curved, area-specific Gracey curette working ends
Working Profile Angled and offset working profile
Shaft Angled terminal shanks
Handle Cylindrical knurled handle
Material Surgical Grade Stainless Steel
Finish Metallic finish
Construction Double-ended hand instrument
Sterilization Autoclavable
Reusable Yes
Application Area Periodontology / Dental Hygiene

Description

The Gracey Periodontal Curette Fig. 12/13 is a double-ended periodontal hand instrument designed for professional periodontal debridement and root-surface instrumentation. The supplied image provides direct identification through the visible “Fig. 12/13 Gracey” marking beneath the instrument. The catalogue/model number printed separately is MMI-64-163, corresponding to Gracey Fig. 12/13 in dental instrument catalogues.

The instrument features two curved, offset working ends connected through slender angled shanks to a cylindrical knurled handle. Its double-ended configuration provides two working orientations within a single periodontal instrument. The Gracey 12/13 pattern is part of the recognized series of area-specific periodontal curettes.

Manufactured from Surgical Grade Stainless Steel, the instrument is suitable for repeated professional dental use and routine autoclave sterilization. Its clearly defined Fig. 12/13 pattern allows accurate identification within periodontal and dental hygiene instrument sets.

To maintain the performance, appearance, and service life of your stainless steel dental and surgical instruments, follow these care guidelines:

  • Clean instruments immediately after use to prevent blood, tissue, or debris from drying on the surface.
  • Wash using a neutral pH enzymatic detergent and a soft nylon brush. Avoid abrasive pads, steel wool, or harsh chemicals.
  • Rinse thoroughly with distilled or demineralized water to minimize mineral deposits and corrosion.
  • Dry completely before sterilization or storage, paying special attention to hinges, joints, and serrations where moisture can accumulate.
  • Lubricate hinged and moving instruments regularly with a medical-grade, steam-permeable instrument lubricant to ensure smooth operation.
  • Sterilize using validated autoclave procedures or other approved sterilization methods according to healthcare facility protocols and the instrument’s intended use.
  • Store instruments in a clean, dry environment with tips and cutting edges protected from impact or contact with other instruments.
  • Inspect instruments before each use for wear, corrosion, misalignment, or damage. Remove any defective instrument from service until repaired or replaced.
  • Do not expose stainless steel instruments to bleach, strong acids, high-chloride solutions, or prolonged soaking, as these may cause staining, pitting, or corrosion.
  • Use each instrument only for its intended purpose to preserve precision, functionality, and patient safety.
  • Gracey Fig. 12/13 periodontal curette pattern.
  • Visible “Fig. 12/13 Gracey” identification marking.
  • Double-ended instrument configuration.
  • Two curved, area-specific working ends.
  • Angled and offset working-end profile.
  • Angled terminal shanks.
  • Different orientations of the two working ends.
  • Cylindrical handle design.
  • Knurled gripping surface for controlled handling.
  • Individually poly packed
  • Non-sterile
  • Reusable medical instrument