Sanders Periodontal Knife Fig. 1/2

The Sanders Fig. 1/2 Periodontal Knife is a double-ended dental surgical instrument featuring curved and angled cutting blades, slender shafts and a cylindrical knurled handle. Its design supports controlled incision and excision of gingival and periodontal soft tissue during periodontal procedures. The two working ends provide different orientations for access to the treatment area, while the textured handle supports secure manual handling. Manufactured from Surgical Grade Stainless Steel, the instrument is suitable for professional periodontal use, repeated sterilization and inclusion in gingival and periodontal surgery instrument sets.

Quantity:
0
My Custom Kit 0 items configured

Review Kit (0 items)

  • Your kit is currently empty.

Surgical Grade Material

Crafted from high-quality surgical stainless steel.

Precision Finish

Smooth finish for reliable clinical performance.

Ergonomic Design

Comfortable grip for improved control and handling.

Long Service Life

Built for durability and repeated professional use.

shield-check

Easy Sterilization

Fully autoclavable for safe and efficient sterilization.

Technical Specifications
Specification Details
Product Name Sanders Periodontal Knife, Fig. 1/2
Model Number MMI-64-121
Instrument Type Periodontal knife
Pattern / Figure Sanders Fig. 1/2
Design Double-ended
Working Ends Two periodontal knife blades
Blade Configuration Angled and curved cutting blades
Shaft Curved / angled shafts
Handle Cylindrical knurled handle
Application Periodontal soft-tissue incision and excision
Primary Use Gingival and periodontal soft-tissue procedures
Material Surgical Grade Stainless Steel
Finish Metallic finish
Construction Double-ended hand instrument
Sterilization Autoclavable
Reusable Yes
Application Area Periodontology / Gingival Surgery

Description

The Sanders Periodontal Knife Fig. 1/2 is a double-ended periodontal surgical instrument designed for controlled incision and excision of gingival and periodontal soft tissue. The supplied instrument corresponds to Sanders Fig. 1/2, with catalogue/model number MMI-64-121. Professional dental catalogues consistently list the 64-121 pattern as Sanders Fig. 1/2.

The instrument features two angled working ends with curved periodontal knife blades positioned in opposing orientations. This double-ended arrangement provides two working configurations within a single instrument and allows the appropriate end to be selected according to the direction of access and treatment area.

The slender shafts connect the working ends to a cylindrical knurled handle. The textured handle provides a secure gripping surface for controlled manual manipulation during periodontal procedures.

Manufactured from Surgical Grade Stainless Steel, the instrument is suitable for professional dental use, repeated cleaning and routine autoclave sterilization.

To maintain the performance, appearance, and service life of your stainless steel dental and surgical instruments, follow these care guidelines:

  • Clean instruments immediately after use to prevent blood, tissue, or debris from drying on the surface.
  • Wash using a neutral pH enzymatic detergent and a soft nylon brush. Avoid abrasive pads, steel wool, or harsh chemicals.
  • Rinse thoroughly with distilled or demineralized water to minimize mineral deposits and corrosion.
  • Dry completely before sterilization or storage, paying special attention to hinges, joints, and serrations where moisture can accumulate.
  • Lubricate hinged and moving instruments regularly with a medical-grade, steam-permeable instrument lubricant to ensure smooth operation.
  • Sterilize using validated autoclave procedures or other approved sterilization methods according to healthcare facility protocols and the instrument’s intended use.
  • Store instruments in a clean, dry environment with tips and cutting edges protected from impact or contact with other instruments.
  • Inspect instruments before each use for wear, corrosion, misalignment, or damage. Remove any defective instrument from service until repaired or replaced.
  • Do not expose stainless steel instruments to bleach, strong acids, high-chloride solutions, or prolonged soaking, as these may cause staining, pitting, or corrosion.
  • Use each instrument only for its intended purpose to preserve precision, functionality, and patient safety.
  • Sanders Fig. 1/2 periodontal knife pattern.
  • Double-ended instrument configuration.
  • Two angled periodontal knife blades.
  • Curved cutting working ends.
  • Opposing working-end orientations.
  • Slender curved/angled shafts.
  • Designed for periodontal soft-tissue incision.
  • Suitable for gingival tissue excision.
  • Cylindrical knurled handle for controlled handling.
  • Surgical Grade Stainless Steel construction.
  • Individually poly packed
  • Non-sterile
  • Reusable medical instrument