Skip to main content

Dental Instruments & Supplies

SKU: MMI-53-006-01
Category:
Availability: In Stock

Miller Root Elevator

Miller Root Elevator No. 1 (Left) is a precision dental instrument designed for controlled elevation of teeth and tooth roots during extraction procedures. Its 3.0 mm flat, rounded working blade provides a narrow contact profile for precise positioning, while the left-sided curvature supports directional access. The slightly curved shaft facilitates controlled instrument orientation, and the ergonomic handle provides secure handling. Manufactured from surgical grade stainless steel with a polished finish, it provides durability, corrosion resistance, easy maintenance and reliable performance for repeated professional dental use.

Quantity:
0
My Custom Kit 0 items configured

Review Kit (0 items)

  • Your kit is currently empty.

Surgical Grade Material

Crafted from high-quality surgical stainless steel.

Precision Finish

Smooth finish for reliable clinical performance.

Ergonomic Design

Comfortable grip for improved control and handling.

Long Service Life

Built for durability and repeated professional use.

shield-check

Easy Sterilization

Fully autoclavable for safe and efficient sterilization.

Technical Specifications
Specification Details
Product Name Miller Root Elevator No. 1 (Left)
Model Number MMI-53-006-01
Instrument Type Dental Root Elevator
Pattern Miller No. 1
Design Left-Curved
Application Tooth and Root Elevation
Working End Flat, Rounded and Curved
Tip Design Rounded Flat Blade
Working Profile Narrow
Working End Width 3.0 mm
Shaft Slightly Curved
Handle Ergonomic Solid Handle
Material Premium Surgical Grade Stainless Steel
Finish High-Polish Finish
Construction Precision-Forged and Hand-Finished
Sterilization Fully Autoclavable
Reusable Yes
Application Area Professional dental extraction and root elevation procedures

Description

Miller Root Elevator No. 1 (Left) is a precision dental extraction instrument designed for controlled elevation of teeth and tooth roots during dental extraction procedures. The MMI-53-006-01 features the characteristic Miller No. 1 left-curved configuration with a flat, rounded working blade.

The 3.0 mm working-end profile provides a narrow contact surface for controlled positioning around tooth and root structures. The left-sided curvature allows the working end to be oriented appropriately for procedures requiring left-directional access. Miller No. 1 is documented as a left-sided pattern, while product references describe its blade as flat and rounded.

The slightly curved shaft provides an appropriate working angle while maintaining a compact instrument profile. The rounded blade is designed to establish controlled contact with the tooth or root during elevation, supporting precise manipulation during extraction procedures.

Manufactured from surgical grade stainless steel, the instrument is designed for durability, corrosion resistance and repeated professional use. Its polished surface supports cleaning and maintenance, while the reusable construction is suitable for appropriate sterilization between procedures.

To maintain the performance, appearance, and service life of your stainless steel dental and surgical instruments, follow these care guidelines:

  • Clean instruments immediately after use to prevent blood, tissue, or debris from drying on the surface.
  • Wash using a neutral pH enzymatic detergent and a soft nylon brush. Avoid abrasive pads, steel wool, or harsh chemicals.
  • Rinse thoroughly with distilled or demineralized water to minimize mineral deposits and corrosion.
  • Dry completely before sterilization or storage, paying special attention to hinges, joints, and serrations where moisture can accumulate.
  • Lubricate hinged and moving instruments regularly with a medical-grade, steam-permeable instrument lubricant to ensure smooth operation.
  • Sterilize using validated autoclave procedures or other approved sterilization methods according to healthcare facility protocols and the instrument’s intended use.
  • Store instruments in a clean, dry environment with tips and cutting edges protected from impact or contact with other instruments.
  • Inspect instruments before each use for wear, corrosion, misalignment, or damage. Remove any defective instrument from service until repaired or replaced.
  • Do not expose stainless steel instruments to bleach, strong acids, high-chloride solutions, or prolonged soaking, as these may cause staining, pitting, or corrosion.
  • Use each instrument only for its intended purpose to preserve precision, functionality, and patient safety.
  • Miller No. 1 root elevator configuration.
  • Left-sided curved design for directional access.
  • Designed for controlled tooth and root elevation.
  • 3.0 mm working-end width provides a narrow working profile.
  • Flat, rounded blade provides a defined contact surface.
  • Slightly curved shaft facilitates working-end positioning.
  • Compact working profile supports access around tooth and root structures.
  • Ergonomic solid handle provides secure instrument handling.
  • Precision-forged stainless steel construction provides strength and durability.
  • High-polish finish facilitates cleaning and maintenance.
  • Reusable design suitable for professional dental sterilization protocols.
  • Individually poly packed
  • Non-sterile
  • Reusable medical instrument